Use of Intraoral Welding to Increase the Predictability of Immediately Loaded Computer-Guided Implants
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 37 , Issue 4
July/August 2017

Pages 591–598


Use of Intraoral Welding to Increase the Predictability of Immediately Loaded Computer-Guided Implants

Alberto Maria Albiero, MD/Renato Benato, MD, DMD/Andrea Benato, DDS/Marco Degidi, MD, DDS


PMID: 28609507
DOI: 10.11607/prd.3027

Inaccuracy of computer-guided implant placement may lead to complications when combined with an immediately loaded prefabricated prosthesis. The aim of this case series was to describe the use of an intraoral welding technique to increase the predictability of immediately loaded implants supporting a fixed full-arch prosthesis after computer-guided flapless implant placement. A total of 60 Ankylos plus implants (Dentsply) with a width of 3.5 mm and a length of 8 to 14 mm were placed consecutively in 10 patients. The implants were functionally loaded using the intraoral welding technique on the day of surgery. The accuracy of guided implant placement was assessed by matching the planning cone beam computed tomography (CBCT) scans with postoperative CBCT scans. No mechanical or biologic complications were registered at the 1-year follow-up. The global coronal deviation of implant placement from the guide plan ranged from 0.25 to 2.84 mm (SD: 0.6 mm), with a mean of 1.28 mm. Average angle deviation was 3.42 degrees (range 0.38–7.82 degrees; SD: 1.52 degrees). The global apical deviation ranged between 0.36 and 3.85 mm (SD: 0.71 mm), with a mean of 1.65 mm. Despite the inaccuracy registered, this guided-welded approach allowed successful achievement of a passive fit of the full-arch prosthesis on the inserted implants the same day of the surgery and provided a high implant and prosthetic survival rate at the 1-year follow-up.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help